0825617325
info@trinitygas.co.za
What is wrong with this installation?
Who can spot what's wrong here?
It connected at a 16l gas geyser.
There at least 7 issues with this installation....
Results below
Call / Whatsapp Ian 082 561 7325 so we can make sure your installation is safe.

Answers...
1. Gas Bottle not allowed to be closer than 2m from a drain
2. Orange pipe is not allowed to be used outside ever
3. The 16l Geyer needs 3kgh of gas but.....
4. It connected to a 1kg regulator
5. Bullnose regulators are not allowed to be used outside
6. The gas piping is too small for the run - delivering probably only 0.6kgh of gas for a need of 3kgh
7. No signage indicating gas safter shut off valves
8 For the plumbers, why use big diameter copper to them use a 4mm branded pipe connection?
I'm not even gonna get into the cylinder size and vaporization rates ......
And the client wonders why the Geyser doesn't get hot enough or have enough water pressure
Yes you guessed it, they did the installation themselves which is not only illegal but has created all the problems